Determination of bearing size

Load Factor c1

It is of further importance that the specific surface load factor is included in the static load capacity. Increasing load will reduce the absolute value of the static load capacity by the load factor c1.
Click here to zoom picture!
Load factor GLYCODUR®

Determination of bearing size

Load Distribution Factor c5

Beyond the above mentioned points, the type of load distribution has an effect on the determination of the service life. This is taken into consideration by the load distribution factor c5.
c5 = 1.0 or a point-focal load
(the load is always at the same point of the bearing's perimeter)
c5 = 1.5 for a circumferential load
(the load zone travels around the entire bearing perimeter)